hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.May 1, 2017 · Fluid Power engineering. (8465 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.Chemical process engineering. (26899 members) forum798 - Professional forum and technical support for engineers for Chemical process engineering. Includes problem solving collaboration tools. Forum.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …

Subject: Section VIII-1, UCS-85 (b) and (e) Date Issued: May 31, 1984. File Number: BC82-563. Related Documents: Question (1): A dished head made of P-No. 1 Gr. Nos. 1 and 2 material with a thickness of less than 1¼ in. is hot pressed at a temperature of 1750°F. Are test specimens required under UCS-85 of Section VIII, Division 1, to ...I want to summarize as follows: Rule 1) The direction of the coordinate axis should align with the direction from "Grid A to Grid B" of the bush element. Rule 2) The "positive" direction of your coordinate system …Financial planners explain how to balance stocks and bonds in your 401(k). Your age plays a major factor. By clicking "TRY IT", I agree to receive newsletters and promotions from M...

Posting in the Eng-Tips forums is a member-only feature. Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Engineering project management general discussion. Includes problem solving collaboration tools.

(RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …Pressure/temperature ratings for Class 800 shall be determined by the equation: P8 = 1/3 P6 + 2/3 P9. where. P8 is the pressure at the specified temperature, expressed in bar3, for Class 800 rounded to the nearest. (10 kpa); P6 is the listed pressure, at the specified temperature, for Class 600, expressed in bar;Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: ABAQUS FEA Solver. Includes problem solving collaboration tools.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ...

Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net Joined March 2009. 124 Following. 295 Followers. Tweets & replies. Media.

Student Engineer General Discussion. (4380 members) forum1630 - Professional forum and technical support for engineers for Student Engineer General Discussion. Includes problem solving collaboration tools. Forum.Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ... Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. My preferred method is to use 3 celas elements for each bolt (2 shears and a tension), and use Huth to obtain the stiffnesses for the FE. The saving grace is that even when you use one of the methods above, in the great scheme of things it makes little difference. RE: Extracting bolt loads from cbush elements. …When you think about shared micromobility, Veo isn’t exactly the first company that comes to mind. It’s not as widespread as competitors like Voi, Tier and Lime, and it hasn’t rais...

Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering …7 Feb 16 11:02. I am designing a isolated footing in SAFE but I am confused that how to check the footing against uplift? Soil pressure are coming as mentioned below. Against dead load Max = -9.08 KN/m^2 and Min = -18 KN/m^2. Against wind load is Max = 53.83 KN/^m2 and Min = -38.74 Kn/m^2. footing is safe against uplift????*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home; Forums; Structural Engineers; Activities; Welding, Bonding & Fastener …As a foundry engineer in a Aluminnum foundry we fight this with customers all the time. #1- Aluminum has roughly 1/2 the Brinell of iron ( hardness) thiss means if you used 6 - 3/8X16 x 1 bolts on a iron part you better look at. using 10 1/2 x 13 x 1.5 in aluminum. We also push Heli coils.All the handrails have to meet the requirements. Loading one side vs the other side is really irrelevant to the handrails and its connections. If there is some loading you are concerned about the in the elements supporting the handrails you might want to consider the loading on each of them simultaneously or perhaps just one side.

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Bell 407 Boeing VR-7 Narramore 8%. Bell 409 YAH-63 Wortmann FX 69-H-083 Wortmann FX 69-H-083. Bell 412 Boeing VR-7 Wortmann FX 69-H-080. Bell 427 Boeing VR-7 Narramore 8%. Bell 47G-2 H-13G wood blades NACA 0017 NACA 0011. Bell 47G-2 H-13H metal blades NACA 0015 NACA 0015. Bell 47J HUL wood blades NACA …

Steel Stair Seismic Design. I have posted a couple of threads regarding this subject in the past, but I would like to post a more thourough question regarding providing seismic design on steel stairs. I have a particular project which is in the Missouri area and is governed by the 2006 IBC and ASCE 7-05. I have …It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …In ASCE 7-22, partially open is included in those. My assumption is that they messed up and forgot to include it in ASCE 7-16. My tin-foil hat opinion: Partially open was added simply because we aren't comfortable labeling buildings that are THAT "open" as "enclosed."Nigeria’s broadcast regulator, the National Broadcasting Commission, has ordered all broadcasting stations in the country to suspend their use of Twitter. The directive was issued ...PE Structural CBT April 2024. I am beginning to study for the the new PE Structural (SE) exam that is a computer based test (CBT) beginning in April 2024. All prep courses I have seen online are for the existing SE exam. I am wondering if anyone else is studying for the new format SE exam and how you are going about studying.Construction Process2. Construction Process. 2. As a new junior engineer without much construction experience, I wanted to ask whether there is a trustworthy resource which goes into a detailed narrative of the construction process, encompassing from the beginning paperwork, typical teams making up a project, …Antenna & propagation engineering. Circuit design. Communication & signal processing engineering. Electric motors & generators engineering. Electric power & transmission & distribution. Electrical Engineering general discussion. Microwave & electromagnetic engineering. Power supply & electronic component design. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum.

woman with red coat walking up the stairs to the clouded sky Cancer Matters Perspectives from those who live it every day. Your email address will not be published. Required fields...

The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is …

GENEVA (11 March 2024) — Syria is experiencing a wave of violence not seen since 2020, the UN Syria Commission of Inquiry warned in a report released today. …Rules of Thumb - Structural Engineering Other Technical Topics FAQ - Eng-Tips - Free download as PDF File (.pdf), Text File (.txt) or read online for free. For a "rule of thumb" …Joel - I tried to configure (imagine) a non-prestressed concrete tank that had H^2 / Dt > 50. Hard to do. For both the considerations of the combined shear + flexural demand at the base, and shrinkage, tall non-prestressed concrete tanks are uncommon, and I certainly would try to persuade you toward either steel or prestressed (DYK / DN) Type … Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering games, videos, jobs, disciplines, calculators and articles… Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. Ignition, Combustion and Detonation engineering. Laser engineering. Mechanical Seal engineering. Mechanical Acoustics/Vibration engineering. Optical systems engineering. Pipelines, Piping and Fluid Mechanics engineering. Pump engineering. Storage tank engineering. Valve engineering. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... thread404-515636. Dynamo2000 (Mechanical) (OP) 19 Jan 24 21:00. Very recently in the news was an invention called the Holo Tile Floor created by Disney's National Inventors Hall of Fame member Lanny Smoot. This creation allows the user to "walk" in any direction without moving anywhere! The floor shifts to compensate for the user's leg …Its total height is 140 mm, where height of steel deck is 60 mm and height of concrete above slabs is 80 mm, so I've put that both membrane and bending thicknesses are 140mm = 0,14m. As a material I've chosen concrete C30/37 defined in Materials (I'll attach my model in SAP2000 at the end of the post). This concrete's Weight per Unit Volume is ...Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.(RTTNews) - Himax Technologies, Inc. (HIMX) reported that its second quarter profit to stockholders declined to $70.64 million from $108.89 millio... (RTTNews) - Himax Technologies...

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search.JAE (Structural) 9 Feb 11 21:01. Sounds like you got it. wannabeSE (Civil/Environmental) 9 Feb 11 21:13. If you are anchoring the equipment to masonry or concrete, look at ASCE 7-05 section 13.4.2. You may need to multiply the seismic force by 1.3. Also, if the anchors are not prequalified for seismic, you may need to … Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other users. The targeted audience of Eng-Tips is engineering professionals. Instagram:https://instagram. tiffany mcghie obituarysono bello addison reviewstlcafrica2what time does kohl's close Eng-Tips Groups Engineering Language/Grammar Skills Engineers with Hobbies Local Exhaust Ventilation NICET Certification, training and education Pats' Pub Translation Assistance for Engineers. People Aeronautics & Space Engineers Activities Aeronautic & Space engineering general discussion Aircraft engineering Rotorcraft engineering …Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.) rurusama9 nudeprimanti brothers order online forum337 - Professional forum and technical support for engineers for Wood design and engineering. Includes problem solving collaboration tools. Search.DASSAULT: CATIA products. (15414 members) forum560 - Professional forum and technical support for engineers for DASSAULT: CATIA products. Includes problem solving collaboration tools. Forum. Search. what time does the walmart pharmacy open on saturday China and Europe remain the most important electric vehicle markets. Electric vehicles (EVs for short) are no longer just cool toys reserved for wealthy futurists. They are becomin...I attached a drawing just in case I can't explain myself clear enough. Anyway, I read that 'A relief valve is only needed if no other measures are provided to detect low flow conditions and shut down the centrifugal pump to prevent damage', well in my situation, there isn't a flow measuring instrument installed upstream of …